Ways to Prevent Underground Utility Strikes
Reference & Education → Education
- Author Peter Ashcroft
- Published September 1, 2019
- Word count 647
Utility network infrastructure comprising of telecommunications, electricity, gas, water and other such utilities play an integral role in the economic health of any country. As smart cities are growing at an exponential rate, the dependency on more complex and larger networks of utilities are constantly on the rise and it is stimulating rapid growth. On the other hand, ageing cities are struggling to maintain their existing infrastructure or even find space for new installations.
To keep these important services running, modernisation programmes and repairs have to be conducted, which results in copious amounts of street works. The ground has to be excavation to be able to reach the underground utilities. 1.5 million street works are annually carried out in the UK alone.
However, undertaking any kind of excavation work brings the site workers in close proximity to the buried utilities. Damaging or puncturing the protective sheath around a buried utility service leads to the creation of disruption, considerable repair costs and project delays. This event is usually referred to as utility or service strike, and is often fatal. This is why consideration should be given to locating the exact place where the utilities are buried before excavation begins.
Below given are some of the steps that can be implemented to prevent a cable strike from happening.
Implementation of safe working practices
More than half of all cable strikes are to electrical cables. A majority of them are caused by air powered tools, mini diggers and metal hand tools. This dangerous combination poses the highest risk to all the workers present at the site.
A large number of cable strikes happen in the absence of safe working practices. So, it is important that before the start of any kind of excavation project, safe working practices are implemented and ensured that all the workers are following it.
In the UK, HSG47 is the government standard that has been put in place in order to reduce the risk of utility strikes. It is expected that any site where excavation is involved, the rules and regulations of this standard is going to be followed. One of the rules of this standard is the early detection and location of the buried utilities.
A desktop survey
All excavation teams are expected to undertake a thorough desktop survey to avoid striking an underground utility service. During the survey, the excavation teams will have to collate existing records given by the owners, as well as, the operators of the utilities. However, you must not only rely on utility plans as your ultimate source of information. You need to also carry out a geophysical site survey to cross-check the records.
Undertake a site reconnaissance
The utility records must not be trusted blindly. It is vital that you carry out a physical site reconnaissance to verify the utility records and look for inconsistencies. For this, you can use CAT & Genny as they are one of the best cable avoidance tools. Whilst CAT helps in detecting and locating live wires, Genny helps to generate a signal on wires that are not live. When these equipment are used together, it can help you detect and locate almost all underground utility service. You can mark the areas and ensure to maintain a safe distance when the digging starts.
Train the excavation team
Lack of proper training leads to increasing the risk. Since the site workers are going to be in such close proximity with the utility services, it is important that they are training for the task. Untrained workers lead to causing utility strikes that jeopardise the life of the other workers who are on the site.
The thing about utility strikes is that they can be prevented with a little bit of training and knowledge. You need to find a professional training provider and learn the use of cable avoidance tools. Such programmes are designed to help prevent cable strikes.
Sygma Solutions Ltd. is the trusted CAT & Genny training provider in the UK. They have an experienced team with years of expertise in the use of cable avoidance tools. Their training programmes are specifically designed to include both practical and theoretical knowledge so that cable strike can be prevented.
Article source: https://articlebiz.comRate article
Article comments
There are no posted comments.
Related articles
- IT TAKES A VILLAGE
- Closing the Digital Gap: Overcoming Accessibility Barriers for Students with Disabilities in Benin City
- Expert Quran Teacher for Kids and Adults
- Why is the study of history is critical?
- First Aid Courses and CPR Training - Safety Learning
- A META-ANALYSIS ON THE IMPACT OF CRAMMING AS LEARNING STRATEGIES AMONG SHS STUDENTS IN GHANA
- Revolutionize Your School's Online Presence with a Cutting-Edge CMS Website Development
- How to Find Emotive Language in a Text: A Comprehensive Guide
- Addressing the Rise of Academic Pressure
- Standard Thickness of Asphalt Pavement
- The Importance of Character Education from an Early Age
- Education, Evolution & AI - Mixing Technology and Learning in the 21st Century
- Obtain Full G Driver’s License in Ontario
- Top Tips for Writing High-Scoring University Assignments Insights from Assignment Experts
- Parents Guide to Finding the Best Bay Area Tutoring for Your Child
- The Ultimate Guide to Choosing the Top Driving School in Manhattan
- Gearing Up: Automatic vs. Manual Driving Lessons
- Unified Field Theory Is Explainable
- Project Management in the Digital Age: Leveraging Technology for Success
- Progressing through the Lean Six Sigma Belt Levels: A Journey from White to Black
- A part of Crisis at school: School violence
- Unlocking Success: Why Phonological Awareness Matters for Kids and How to Support It
- Unlocking the Power of Assessment: Strategies for Effective Evaluation
- Unlocking Intellectual Potential: Edinburgh, UK Manuscript Illustrations
- Viruses, structures, causes and prevention
- the importance of stars
- Love and Limits: How to set limits while preserving loving relationships with students
- Unveiling the Potential: A Comprehensive Exploration of "Crushing It With Crypto 2024: UNLOCKED"
- The Evolution of Artificial Intelligence: Past, Present, and Future
- The Impact of the War in Ukraine on the School Study Process